About DELTA
sfsdfsd
| DELTA PLC Models - Selection Chart Summary |
| SS2 | SA2 | SE | SV | ES2 | EH2 | EX2 | SX |
| | | | | | | | |
| DVP14SS211R/T | DVP12SA211R/T | DVP12SE11R/T | DVP28SV11R/T | DVP16ES200R/T | DVP16EH00R2/T2 | DVP20EX200R/T | DVP20SX211R/S/T |
| DVP08SN11R/T | DVP08SN11R/T | DVP08SN11R/T | DVP28SV11R2/T2 | DVP24ES200R/T | DVP20EH00R2/T2 | | DVP08SN11R/T |
| DVP16SP11R/T | DVP16SP11R/T | DVP16SP11R/T | DVP08SN11R/T | DVP32ES200R/T | DVP32EH00R2/T2 | | DVP16SP11R/T |
| DVP16SP11TS | DVP16SP11TS | DVP16SP11TS | DVP16SP11R/T | DVP40ES200R/T | DVP32EH00M2 | | DVP16SP11TS |
| DVP16SM11N | DVP16SM11N | DVP16SM11N | DVP16SP11TS | DVP60ES200R/T | DVP40EH00R2/T2 | | DVP16SM11N |
| DVP08SP11R/T | DVP08SP11R/T | DVP08SP11R/T | DVP16SM11N | DVP32XP200R/T | DVP48EH00R2/T2 | | DVP08SP11R/T |
| DVP08SM11N | DVP08SM11N | DVP08SM11N | DVP08SP11R/T | DVP24XP200R/T | DVP64EH00R2/T2 | | DVP08SM11N |
| DVP06SN11R | DVP06SN11R | DVP06SN11R | DVP08SM11N | DVP24XN200R/T | DVP80EH00R2/T2 | | DVP06SN11R |
| DVP32SM11N | DVP32SM11N | DVP32SM11N | DVP06SN11R | DVP08XN211R/T | DVP08HP11R/T | | DVP32SM11N |
| DVP04AD-S | DVP04AD-S | DVP04AD-S | DVP32SM11N | DVP08XP211R/T | DVP08HM11N | | DVP04AD-S |
| DVP04DA-S | DVP04DA-S | DVP04DA-S | DVP04AD-S | DVP16XN211R/T | DVP08HN11R/T | | DVP04DA-S |
| DVP02DA-S | DVP02DA-S | DVP02DA-S | DVP04DA-S | DVP08XM211N | DVP16HM11N | | DVP02DA-S |
| DVP04PT-S | DVP04PT-S | DVP04PT-S | DVP02DA-S | DVP16XM211N | DVP16HP11R/T | | DVP04PT-S |
| DVP04TC-S | DVP04TC-S | DVP04TC-S | DVP04PT-S | DVP16XP211R/T | DVP32HP00R/T | | DVP04TC-S |
| DVP06XA-S | DVP06XA-S | DVP06XA-S | DVP04TC-S | DVP02DA-E2 | DVP48HP00R/T | | DVP06XA-S |
| DVP06AD-S | DVP06AD-S | DVP06AD-S | DVP06XA-S | DVP04DA-E2 | DVP32HN00R/T | | DVP06AD-S |
| | | | DVP06AD-S | DVP04AD-E2 | DVP04AD-H2 | | |
| | | | | DVP06XA-E2 | DVP04DA-H2 | | |
| | | | | DVP04PT-E2 | DVP04PT-H2 | | |
| | | | | DVP04TC-E2 | DVP04TC-H2 | | |
| | | | | | DVP06XA-H2 | | |
DELTA PLC
- Dealers
- Distributors
- System Integration & Turn Key Project Solutions
- Services
- PLC Programming
- Design of Control Panel & Manufacturing
- Installation
- Commissioning
- Wiring
- Tracing
- Integration with HMI , Temperature Controller , Digital Inputs & Outputs , Remote IO's , RS485 / RS232 Communication Modules , Ethernet , Ethercat , Motion Controllers of PM Series
Versatile Motor Compatibility and Control MethodsDELTA AC Drive is engineered for both three-phase induction and permanent magnet motors, delivering flexible integration into existing systems. Its sophisticated vector control and V/F control modes ensure precise motor performance adapted to a variety of industrial automation needs, providing accurate speed and torque management.
Robust Protection and Reliable PerformanceEquipped with comprehensive protection mechanismsovervoltage, undervoltage, overcurrent, and overtemperaturethe DELTA AC Drive safeguards your machinery. The built-in fan cooling, sturdy ABS construction, and IP20/IP54 dust and water resistance ensure continuous, stable operation in rigorous indoor environments.
User-Friendly Programming and ConnectivityThe drive features an intuitive programming interface via digital keypad or external PC, simplifying setup and parameter adjustment. It supports industry-standard Modbus and RS485 communication protocols, enabling seamless system integration and remote operation when required, enhancing control flexibility and automation efficiency.
FAQs of DELTA:
Q: How can the DELTA AC Drive be programmed and configured for operation?
A: The DELTA AC Drive can be programmed using its integrated digital keypad or through a connected external PC. This allows users to easily set parameters, adjust acceleration/deceleration times (0.1 to 6000 seconds), and switch between vector and V/F control modes to suit their application requirements.
Q: What motor types are compatible with this AC drive, and in what applications can it be used?
A: This drive supports both three-phase induction motors and permanent magnet motors, making it ideal for industrial automation, HVAC systems, machine control, and conveyor operations where variable speed and precise control are needed.
Q: Where should the DELTA AC Drive be installed to ensure optimal performance and safety?
A: The DELTA AC Drive is designed for indoor use only and should be mounted on a panel or wall in a location with maximum 95% non-condensing humidity and temperature between -10C to +50C. Ensure adequate ventilation for its fan cooling system and compliance with its IP20 or IP54 rating for protection against dust and water.
Q: What protection features does the DELTA AC Drive offer for continuous and overload operation?
A: It provides comprehensive fault protection, including overvoltage, undervoltage, overcurrent, and overtemperature safeguards. The drive can handle loads up to 150% for 60 seconds, ensuring reliability during peak demand while preventing damage to the equipment.
Q: How does the DELTA AC Drive support remote control and system connectivity?
A: The drive is compatible with Modbus and RS485 communication protocols, which allow easy integration into automation networks. Remote monitoring and control are supported, so users can adjust parameters or check status without needing direct access to the unit.
Q: What are the key benefits of using the DELTA AC Drive for industrial automation and energy savings?
A: The DELTA AC Drive provides precise speed control, energy savings through efficient motor management, and robust protection features. Its advanced processor and sensorless vector control enhance motor response, reduce downtime, and help lower operational costs for industrial applications.